Yosun (Tianjin) Piping Engineering Co., Ltd. is one of the most credible manufacturers and suppliers of galvanized coating in China. Please feel free to wholesale customized galvanized coating at competitive price from our factory. If you have any enquiry about quotation, please feel free to email us.
Significance and Use
1.This practice is designed to locate the thinnest portions of the zinc cating on newly coated items [see appendix X1].Variations in coating thickness can be due to the process by which the zinc is applied[hot dipped,electroplated,or sprayed ] or by the geometry of the part that is coated.During hot-dip galvanizing,the coating thickness is affected by the drainage pattern of the molten zinc,while during zinc spraying [metallizing],coating thickness can be dependent on the operator's manipulation of the spray nozzle.The geometry of the part can aslo influence coating thickness especially during hot-dip galvanizing,where peaks and valleys on the part can cause molten zinc to build up or thin out.This pratice is designed to identify those areas of the part where the coating is thin.
Specimen Rinse Water
Ordinary,clean tap water may be used for rinsing specimens.If no running tap water is available,the rinse water shall be changed after each dip. The temperature of the rinse water shall be from 15 to 21℃[60 to 70°F].
End Point
1.The end point shall be recognized by the appearance of bright,adherent copper deposits.However,if such a deposit fails to form after the comolete disappearance of the zinc coating,the immersion succeeding the disaooerance of the zinc shall be recognized as representing the end point.
2.Confirm adherence of the bright copper deposit by a peeling test.If it is possible to remove the copper with an ink eraser or to peel the copper with the edge of a blunt tool such as the back of a knife blade,and zinc appears underneath the copper,such an appearance of deposited copper shall not be construed as an end point.
3.A fine line appearance of copper on the top of screw threads or on sharp edges of articles,or within 1 in.[25 mm] of a cut portion of a specimen,shall not be judged as an end point.Likewise,the indication of bright adherent deposits of copper at or adjacent to any cut or abrasion present on the original specimen shall not be considered an end point.
Supplementary Tests
1.If at any time during the immersion procedure there is any doubt as to the presence of exposed base metal,as determined by visual inspection,there are several supplementary tests described in Section 10, one or more of which may be used depending on the type of coating being evaluted.