々 Single wall techniques-Class A
|
Specified wall thickness T |
Wire number Diameter |
Specified wall thickness T |
Hole number Diameter |
Specified wall thickness T |
Duplex IQIab | |
| Unsharpness | Wire diameter and spacing | |||||
| T≤1.2 |
W18 0.063 |
T≤ 2 |
H3 0.20 |
T≤2 |
D11 0.6 |
0.080 |
| 1.2<T ≤2 |
W17 0.08 |
2<T ≤3.5 |
H4 0.25 |
2<T ≤5 |
D10 0.20 |
0.100 |
| 2< T≤3.5 |
W16 0.10 |
3.5<T ≤6 |
H5 0.32 |
5<T ≤10 |
D9 0.26 |
0.130 |
| 3.5<T ≤5 |
W15 0.13 |
6<T ≤10 |
H6 0.40 |
10<T ≤25 |
D8 0.32 |
0.160 |
| 5< T≤7 |
W14 0.16 |
10<T ≤15 |
H7 0.50 |
25<T ≤55 |
D7 0.40 |
0.200 |
| 7< T≤10 |
W13 0.20 |
15<T ≤24 |
H8 0.64 |
55< T |
D6 0.50 |
0.250 |
| 10< T≤15 |
W12 0.25 |
24<T ≤30 |
H9 0.80 |
|||
| 15<T ≤25 |
W11 0.32 |
30<T ≤40 |
H10 1.00 |
|||
| 25<T ≤32 |
W10 0.40 |
40<T ≤60 |
H11 1.25 |
|||
| 32<T ≤40 |
W9 0.50 |
60< T |
H12 1.60 |
|||
| 40<T ≤55 |
W8 0.63 |
|||||
| 55<T |
W7 0.80 |
|||||
|
a Duplex IQI should be used in conjunction with either a wire or step/hole IQI. b Duplex IQI should be examined using a profile display;the smallest wires whicj have a dip separation below 20 % between the wire pair determine the unsharpness. |
||||||
々 Single wall techiques-Class B
|
Specified wall thickness T |
Wire number Diameter |
Specified wall thickness T |
Hole number Diameter |
Specified wall thickness T |
Duplex IQIab | |
| Unsharpness | Wire diameter and spacing | |||||
| T≤1.5 |
W19 0.05 |
T≤2.5 |
H2 0.16 |
T≤1.5 |
D13+ <0.40 |
< 0.05 |
| 1.5<T≤2.5 |
W18 0.063 |
2.5< T≤4 |
H3 0.20 |
1.5< T≤4 |
D13 0.10 |
0.05 |
| 2.5<T ≤4 |
W17 0.08 |
4< T≤8 |
H4 0.25 |
4< T≤8 |
D12 0.13 |
0.065 |
| 4<T ≤6 |
W16 0.10 |
8< T≤12 |
H5 0.32 |
8< T≤12 |
D11 0.16 |
0.080 |
| 6<T ≤8 |
W15 0.13 |
12< T≤20 |
H6 0.40 |
12< T≤40 |
D10 0.20 |
0.100 |
| 8<T ≤12 |
W14 0.16 |
20< T≤30 |
H7 0.50 |
40< T |
D9 0.26 |
0.130 |
| 12<T ≤20 |
W13 0.20 |
30< T≤40 |
H8 0.65 |
|||
| 20<T ≤30 |
W12 0.25 |
40< T≤60 |
H9 0.80 |
< T≤ | ||
| 30<T ≤35 |
W11 0.32 |
60< T |
H10 1.00 |
|||
| 35<T ≤45 |
W10 0.40 |
|||||
| 45<T ≤65 |
W9 0.50 |
|||||
| 65< T |
W8 063 |
|||||
|
NOTE D13+ is achieved if the duplex wire paor D13 is resolved with a dip> 20% a Duplex IQI should be used in conjunction with either a wire or step/hole IQI. b Duplex IQI should be examined using a profile display;the smallest wires which have a dip separation below 20% between the wire pair determine the unsharpness. |
||||||