Bend Test
For pipe used for coiling in size 2 in. and under a bend test is made to determine its ductility and the soundness of weld.In this test a sufficient length of full-size pipe is bent cold through 90° around a cylindrical mandrel habing a diameter 12 times the nominal diameter of the pipe.For close coiling,the pipe is bent cold through 180° around a mandrel having a diameter 8 times the nominal diameter of the pipe.
Transverse Strip Test Specimens
1.In general,transverse tension tests are not recommended for tubular products,in sizes smaller than 8 in. in nominal diameter.When required,transverse tension test specimens may be taken from rings cut from ends of tubes or pipe as shown in Fig.A2.4.Flattenting of the specimen may be done either after separating it from the tube as in Fig.A2.4[a], or before separating it as in Fig.A2.4[b],and may be done hot or cold;but if the flattening is done cold,the specimen may subsequently be normalized.Specimens from tubes or pipe for which heat treatment is specified,after being flattened either hot or cold,shall be given the same treatment as the tubes or pipe.For tubes or pipe having a wall thickness of less than 3/4 in.[19 mm], the transverse test specimen shall be of the form and dimensions shown in Fig,A2.5 and either or both surfaces may be machined to secure uniform thickness.Specimens for transverse tension tests on welded steel tubes or pipe to determine strength of welds,shall be located perpendicular to the welded seams with the weld at about the middle of their length.
2.The width should be measured at each end of the gauge length to determine parallelism and als at the center.The thickness should be measured at the center and used with the center measurement of the width to determine the cross-sectional area.The center width dimension should be recorded to the nearest 0.005 in.[0.127 mm],and the thickness measurement to the nearest 0.001 in.[0.025 mm].