[Permissible variations in dimensions]
| specified size of holes | ±1/32 in.[0.8 mm] | |
| specified location of holes | ± 1/16 in.[1.6 mm] | |
| specified length of bar | ±1/8 in.[3.2 mm] | |
| maximum camber in either plane-tee rail appliications(see 7.3) | ||
| grades 1.2 | grade 3 | |
| 24-in.[610-mm] bars | 1/16 in.[1.6 mm] | 1/32 in.[0.8 mm] |
| 36-in.[914-mm] bars | 1/8 in.[3.2 mm] | 1/16 in. [1.6 mm] |
| maximum vertical camber-girder eail applications [see 7.3] [grades 1 and 2 only] | ||
| 24-in.[610-mm] bars | 3/64 in.[1.2 mm] | |
| 36-in.[914-mm] bars | 3/32 in.[2.4 mm] | |
| maximum hirizontal comber-girder rail applications[see 7.4] [grades 1 and 2 only] | ||
| 24-in.[610-mm] bars | 1/16 in.[1.6 mm] | |
| 36-in.[914-mm] bars | 1/8 in.[3.2 mm] | |
[Inspection]
The manufacturer shall afford the purchaser's inspector all reasonable facilities necessary to satisfy that the material is being produced and furnished in accordance with this specification.Mill inspection by the purchaser shall not interfere unnecessarily with the manufacturer's operations.All tests and inspections shall be made at the place of manufacture,unless otherwise agreed upon.