Definitions Of Magnetic Testing

Nov 18, 2025

Leave a message

Definition of Terms Used in Magnetic Testing

ac excitation, N1I/ℓ1-the ratio of the rms ampere-turns of exciting current in the primary winding of an inductor to the effective flux path length of the inductor.
active (real) power, P-the product of the rms current, I, in an electrical circuit, the rms voltage, E, across the circuit, and the cosine of the angular phase difference, θ between the current and the voltage.
P = EI cosθ
    DISCUSSION-The portion of the active power that is expended in a magnetic core is the total core loss, PC.
 
aging coefficient-the percentage change in a specific magnetic property resulting from a specific aging treatment.
    DISCUSSION-The aging treatments usually specified are:
(a) 100 h at 150°C or
(b) 600 h at 100°C.
aging, magnetic-the change in the magnetic properties of a material resulting from metallurgic change due to a normal or specified aging condition.
    DISCUSSION-This term implies a deterioration of the magnetic properties of magnetic materials for electronic and electrical applications, unless otherwise specified.
air-gap magnetic field strength, Hg-the magnetic field strength required to produce the induction existing at some point in a nonmagnetic gap in a magnetic circuit.
    DISCUSSION-In the cgs-emu system of units, Hg is numerically equal to the induction existing at such a point and exceeds the magnetic field
strength in the magnetic material.
amorphous alloy-a semiprocessed alloy produced by a rapid quenching, direct casting process resulting in metals with noncrystalline structure.
ampere (turn), A-the unit of magnetomotive force in the SI system of units. The symbol A represents the unit of electric current, ampere, in the SI system of units.
ampere per metre, A/m-the unit of magnetic field strength in the SI system of units.
anisotropic material-a material in which the magnetic properties differ in various directions.
anisotropy of loss-the ratio of the specific core loss measured with flux parallel to the rolling direction to the specific core loss with flux perpendicular to the rolling direction.
anisotropy of loss 5
news-635-229
    DISCUSSION-This definition of anisotropy normally applies to electrical steels with measurements made in an Epstein frame at a flux density of 15 kG [1.5 T] and a frequency of 60 Hz (see Test Method A343).
anisotropy of permeability-the ratio of relative peak permeability measured with flux parallel to the rolling direction to the relative peak permeability measured with flux perpendicular to the rolling direction.
news-659-319
antiferromagnetic material-a feebly magnetic material in which almost equal magnetic moments are lined up antiparallel to each other. Its susceptibility increases as the temperature is raised until a critical (Neél) temperature is reached; above this temperature the material becomes paramagnetic.
apparent power, Pa-the product (volt-amperes) of the rms exciting current and the applied rms terminal voltage in an electric circuit containing inductive impedance. The components of this impedance as a result of the winding will be linear, while the components as a result of the magnetic core
will be nonlinear. The unit of apparent power is the voltampere, VA.
apparent power, specific, Pa(B;f)-the value of the apparent power divided by the active mass of the specimen, that is, volt-amperes per unit mass. The values of voltage and current are those developed at a maximum value of cyclically varying induction B and specified frequency f.
area, A-the geometric cross-sectional area of a magnetic path which is perpendicular to the direction of the induction.
Bloch wall-a domain wall in which the magnetic moment at any point is substantially parallel to the wall surface. See also domain wall.
Bohr magneton-a constant that is equal to the magnetic moment of an electron because of its spin. The value of the constant is (9 274 078 × 10−21 erg/gauss or 9 274 078 × 10−24 J/T).
cgs-emu system of units-the system for measuring physical quantities in which the base units are the centimetre, gram, and second, and the numerical value of the magnetic constant, µ0, is unity.
coercive field strength, Hc-the (dc) magnetic field strength required to restore the magnetic induction to zero after the material has been symmetrically cyclically magnetized.
coercive field strength, intrinsic, Hci-the (dc) magnetic field strength required to restore the instrinsic magnetic induction to zero after the material has been symmetrically cyclically magnetized.
coercivity, Hcs-the maximum value of coercive field strength that can be attained when the magnetic material is symmetrically cyclically magnetized to saturation induction, BS.
core, laminated-a magnetic component constructed by stacking suitably thin pieces of magnetic material which are stamped, sheared, or milled from sheet or strip material. Individual pieces usually have an insulating surface coating to minimize eddy current losses in the assembled core.
core, mated-two or more magnetic core segments assembled with the magnetic flux path perpendicular to the mating surface.
core, powder (dust)-a magnetic core comprised of small particles of electrically insulated metallic ferromagnetic material. These cores are characterized by low hysteresis and eddy current losses.
core, tape-wound-a magnetic component constructed by the spiral winding of strip material onto a suitable mandrel. The strip material usually has an insulating surface coating which reduces interlaminar eddy current losses in the finished core.
core loss, ac eddy current, incremental, P∆e-the power loss caused by eddy currents in a magnetic material that is cyclically magnetized.
core loss, ac eddy current, normal, Pe-the power losses as a result of eddy currents in a magnetic material that is symetrically cyclically magnetized.
    DISCUSSION-The voltage is generally assumed to be across the parallel combination of core inductance, L1, and core resistance, R1.
core loss, ac, incremental, Pc∆-the core loss in a magnetic material when the material is subjected simultaneously to a dc biasing magnetizing force and an alternating magnetizing force.
core loss, residual, Pr-the portion of the core loss power, Pc, which is not attributed to hysteresis or eddy current losses from classical assumptions.
core loss, ac, specific, Pc(B;f)-the active power (watts) expended per unit mass of magnetic material in which there is a cyclically varying induction of a specified maximum value,B, at a specified frequency, f.
core loss, ac, (total), Pc-the active power (watts) expended in a magnetic circuit in which there is a cyclically alternating induction.
    DISCUSSION-Measurements of core loss are normally made with sinusoidally alternating induction, or the results are corrected for deviations from the sinusoidal condition.
core loss density-the active power (watts) expended in a magnetic core in which there is a cyclically varying induction of a specified maximum value, B, at a specified frequency, f, divided by the effective volume of the core.
    DISCUSSION -This parameter is normally used only for non-laminated cores such as ferrite and powdered cores.
core plate-a generic term for any insulating material, formed metallurigically or applied externally as a thin surface coating, on sheet or strip stock used in the construction of laminated and tape wound cores.
coupling coefficient, k'-the ratio of the mutual inductance between two windings and the geometric mean of the individual self-inductances of the windings.
crest factor, cf-the ratio of the maximum value of a periodically alternating quantity to its rms value.
    DISCUSSION-For a sinusoidal variation the crest factor is√2 .
Curie temperature, Tc-the temperature above which a ferromagnetic or ferrimagnetic material becomes paramagnetic.
current, ac core loss, Ic-the rms value of the in-phase component (with respect to the induced voltage) of the exciting current supplied to a coil which is linked with a ferromagnetic core.
current, ac exciting, I-the rms value of the total current supplied to a coil that is linked with a ferromagnetic core.
    DISCUSSION-Exciting current is measured under the condition that any other coil linking the same core carries no current.
current, ac, magnetizing, Im-the rms value of the magnetizing component (lagging with respect to applied voltage) of the exciting current supplied to a coil that is linked with a ferromagnetic core.
current, dc, Idc-a steady-state dc current. A dc current flowing in an inductor winding will produce a unidirectional magnetic field in the magnetic material.
customary units-a set of industry-unique units from the cgs-emu system of units and U.S. inch-pound systems and units derived from the two systems.
    DISCUSSION-Examples of customary units used in ASTM A06 standards include:
Quantity Name
Quantity
Symbol
Unit Name
Unit Symbol
Magnetic field strength
H
oersted
Oe
Magnetic induction (magnetic
flux density)
B
gauss
G
Specific core loss
Pc(β; f)
watt/pound
W/lb

 

Send Inquiry