Superheat

Nov 12, 2025

Leave a message

Heat Treatment and Grain Size RequirementsA

Grade
UNS
Number
Heat Treat Type
Austenitizing/
Solutioning/
Stabilizing
Temperature,
min or range °F [°C]
Cooling Media
Subcritical Annealing
or Tempering
Temperature,
min or range °F [°C]
ASTM
Grain Size No.B
Ferritic Alloy Steels
T2
K11547
full or isothermal
anneal; or
- - - -
   
normalize and
temper; or
- - - -
   
subcritical anneal
- -
1200 to 1350
[650 to 730]
-
T5
K41545
full or isothermal
anneal; or
- - - -
   
normalize and
temper
- -
1250 [675]
-
T5b
K51545
full or isothermal
anneal; or
- - - -
   
normalize and
temper
- -
1250 [675]
-
T5c
K41245
subcritical anneal
-
air or furnace
1350 [730]C
-
T9
S50400
full or isothermal
anneal; or
- - - -
   
normalize and
temper
- -
1250 [675]
-
T11
K11597
full or isothermal
anneal; or
- - - -
   
normalize and
temper
- -
1200 [650]
-
T12
K11562
full or isothermal
anneal; or
- - - -
   
normalize and
temper; or
- - - -
   
subcritical anneal
- -
1200 to 1350
[650 to 730]
-
T17
K12047
full or isothermal
anneal; or
- - - -
   
normalize and
temper
- -
1200 [650]
-
T21
K31545
full or isothermal
anneal; or
- - - -
   
normalize and
temper
- -
1250 [675]
-
T22
K21590
full or isothermal
anneal; or
- - - -
   
normalize and
temper
- -
1250 [675]
-
T23
K40712
normalize and
temper
1900–1975
[1040–1080]
-
1350–1470 [730–800]
-
T24
K30736
normalize and
temper
1800–1870
[980–1020]
D
1350–1420 [730–770]
-
T36
K21001
normalize and
temper
1650 [900]
E
1100 [595]
-
T91
K90901
normalize and
temper
1900–1975
[1040–1080]
-
1350–1470 [730–800]
-
T92
K92460
normalize and
temper
1900–1975
[1040–1080]
-
1350–1470 [730–800]
-
T122
K91261
normalize and
temper
1900–1975
[1040–1080]
-
1350–1470 [730–800]
-
T911
K91061
normalize and
temper
1900–1975
[1040–1080]
D
1365–1435
[740–780]
-

AWhere ellipses ({) appear in this table there is no requirement

BASTM Grain Size No. listed, or coarser, unless otherwise indicated.

CApproximately, to achieve properties.

DAccelerated cooling from the normalizing temperature shall be permitted for section thicknesses greater than 3 in. [75 mm].

EAccelerated air cooling or liquid quenching shall be permitted for Class 2.

Send Inquiry